House Wiring |
Having a dream home is the most coveted
wish of all mankind. But keeping it properly lighted with secured
electrification is also another highly important area that all home dwellers
need to keep in mind. To obtain best wiring facility, Chanda
Overseas is the best company to contact with. They supply a wide
spectrum of exclusive Domestic Household Wires mainly the multi-strand cables
which are mainly manufactured for domestic purposes.
Specifications
of House wirings offered by Chanda Overseas
- Delivers domestic cables and house wiring products that are ISI certification
- Delivers verified cables such as LAN cable, Shielded cable, Round cable, Submersible cable etc. that can be fitted by skilled engineers
- Offers wire that contains fire resistant properties
- Home wire insulated with high temperature index and oxygen components
- Home Wire that come in various ranges such as 1 square mm, 1.5 square mm, 2.5 square mm, 4 square mm, 6 square mm, 10 square mm.
- Available in six main colours that are red, black, white, blue, yellow and green
- Keep in mind that conductor must run along the walls and ceilings
- Keep home wiring system on systematic distribution
- Avoid running of wires above ceilings
- Maintain minimum wire system distance of at least 7 feet
- Select wires that contains medium pressure wiring and the associated apparatus certified by ISI specifications
- Keep in mind the minimum load limit on the circuit and that it should not exceed 800 watts
- Remember to circuit power wires need to have 2 points in circuit and the size of the wire should be 1.5mm square for copper and 2mm for aluminium
- Switch board needs to be fitted at a height of 1.5 meter and horizontal wiring need to be at a height of 3 meter
- Having a proper earth facility for the wire gauge is essential. Earth wire for copper wire should be 14 SWG and for aluminium wire it needs to be 4mm
- The fuse wire should be well connected to phase wire and come with a neutral link and connected with a neutral wire
- All the Switches must be connected to phase wire and its minimum size should be 1mm square for copper and 1.5mm square for aluminum cable.
- The conductors must be made of copper wire and have a cross section that is less than 0.0020sq.inches
- Replace any burnt wire, cut or broken wire with fresh wiring. Replace all the rusted points and give attention to circuit fault
- Avoid damaged insulation house wiring to avoid any kind of short circuit faults. Repair all the damaged and loose connections for adequate any earthling faults
No comments: